• Installation

    Installation (74)

  • Studio & Broadcast

    Studio & Broadcast (2)

  • TRANSDUCERS

    TRANSDUCERS (7)

  • Portable & Touring

    Portable & Touring (25)

  • TRK PRO SERIES

    $0.00$199.00
  • AYRA PRO SERIES

    $149.00$549.00
  • MR Series

    $0.00$329.00
  • ART 9-AX Series

    $1,099.00$1,399.00
  • NX Series 2-Way Powered Speakers

    $1,699.00$2,199.00
  • NX Series Stage Monitors

    $1,699.00$2,499.00
  • Active Sub Series

    $1,099.00$5,999.00
  • S Sub Series

    $599.00$2,799.00
  • Description
    E 24 provides eighteen studio-quality 54 dB gain range Mic preamps with combo connectors. Two line inputs are switchable to Hi-Z input. The input section also features three stereo line inputs and a stereo return. Input channels from 1 to 8 are equipped with a single-control compressor. The eighteen mono channels are provided with 4-band EQs, including shelving high and low bands and 2 semi-parametric mid-bands (mid-high and mid-low) with frequency selection and switchable Q choice, wide or narrow. The stereo input channels are provided with a three band EQ.

    PART NUMBER:

    17140087 E 24 EAN 8024530015527 17140112 E 24 US, EAN 8024530017071 17140113 E 24 UK, EAN 8024530017088 17140114 E 24 JP
    Features
    • 18 Mic/line IN, 3 stereo line IN
    • 1 Stereo return input
    • 8 Single-control dynamic compressors (ch.1 - ch.8)
    • 4 Band semiparametric EQ
    • 3 Band EQ on stereo inputs
    • 6 Aux sends per channel
    • 100 mm progressive faders with dust cover
    • 2 Stereo groups
    • 32-Bit floating-point Z.CORE DSP effects section
    For More Info: https://www.rcf.it/en/products/product-detail/e-24
  • Description
    MH 61EN is a two-way plastic horn speaker suitable for both broadcasting alarm messages (thanks to the highly intelligible voice reproduction) and background music, and can be used for sound reinforcement and speech systems in medium and large spaces. The terminal connection blocks, for input and output flameproof cables, are made of ceramic material. A thermal fuse protects the integrity of the line in case of heat affecting the speaker. It can be easily aimed towards any direction through the adjustable wall-mount bracket, and thanks to its IP66 protection grade it can be installed both indoor and outdoor.
    PART NUMBER:
    13100042
    MH 61EN
    EAN 8024530016364
    Features
    • 5" woofer with 1" dome tweeter.
    • Power selectable (100 V): 60 W – 30 W – 15 W – 7.5 W.
    • 99 dB sensitivity.
    • Colour grey RAL 7035.
    • Plastic body.
    • In/out ceramic terminal block.
    • Thermal fuse protection.
    • Protection grade IP66.
  • Description
    MSW 9000 is a monitoring software exclusively dedicated to DXT 9000 Voice Alarm system offering system's real-time monitoring through web interface and SMS notification manager (external service). Connecting thorough a web browser to the IP address of a master unit (stand alone or part of a multi-master system), it is possible to access system’s real-time interface that shows alert/emergency events in progress and active faults on each unit, grouped by categories. The main screen (Dashboard) presents a synthetic view of each master unit in the system, and offers the possibility to access each specific section (Details), with all sub-system detailed information. From the Details page, it is also possible to download the log of events and faults.
    PART NUMBER:
    SW038103
    MSW 9000
    Features
    • Real-time system monitoring
    • Alert/emergency events and faluts signalling
    • Downloadble events and faults log
    • SMS notification manager
  • Description
    MT 7308 is a power amplifiers manager unit of the DXT 7000 Voice Alarm system, suitable to control up to 8 additional power amplifiers and several speaker lines, according to EN 54-16 norm. It works connected to the MU 7100EN master unit. When speaker lines drive high power loads, it could be convenient to optimize the system configuration by using one or more dedicated power amplifiers dimensioned according the loads involved.
    PART NUMBER:
    17170159
    MT 7308
    EAN 8024530007225
    Features
    • Manages up to 8 power amplifiers
    • 500 W maximum power of each amplifier
    • Up to 8 zones managed
    • PC software configuration
  • Description
    SV 7982 is a wall-mount remote control used as local audio control device. It can control a zone group volume and works as program selector. Connection to local or system bus using CAT5 or CAT6 cables.
    PART NUMBER:
    17170140
    SV 7982
    EAN 8024530006365
    Features
    • Zone group control
    • Level control
    • Program Selector
    • CAT5 and CAT6 compatible
  • Description
    PS 6648 is a power supply unit suitable to get continuity power for EN 54-16 systems units like DXT 9000 and DXT 7000, and relevant complementary devices in case of mains power supply interruptions. It includes recharging and monitoring functions for the lead-acid batteries connected to it. It must be equipped with batteries with suitable capacity, dimensioned according to the system power absorption and to the evacuation requirements. According to EN 54-16 standard, it shall be installed into the same rack cabinet where there is the audio system with emergency purposes (or a system part) to which it is connected.
    PART NUMBER:
    17100006
    PS 6648
    EAN 8024530015107
    Features
    • 48 V batteries nominal voltage
    • 6 main outputs to system's units
    • 6 auxiliary outputs
    • Battery circuit control
    • PC software configuration and monitoring
  • Description
    Fire resistant cable suitable for the transmission of audio signals over 100 V speakers lines for voice alarm systems, when maximum safety against fire is required. Made of 2 annealed copper conductors with 2.5 sqmm section. For fixed indoor installations in normal or humid environments. Violet external sheath. Sold in coils of 200 m.
    PART NUMBER:
    14380032
    CV 225
    EAN 8024530012182
    Features
    • Fire resistant cable
    • Suitable for the transmission of audio signals
    • For Voice Alarm systems applications
  • Description
    Shielded CAT5 FTP fire resistant cable suitable for the transmission of signals and commands for voice alarm systems, when maximum safety against fire is required. Made of 4 pairs of twisted annealed copper conductors with 0.63 sqmm (AWG22) section. For fixed indoor installations in normal or humid environments. Red external sheath. Sold in coils of 200 m.
    PART NUMBER:
    12399047
    CJ 428CAT
    EAN 8024530016449
    Features
    • Fire resistant CAT5 FTP shielded data cable
    • Suitable for the transmission of signals and commands
    • For Voice Alarm systems applications
  • Description
    The software allows configuring small and medium VOICE-ALARM systems in accordance to the regulations (prescriptive method), using EN 54-24 loudspeakers and EN 54-16 management electronics of the RCF DXT 3000 Series (250W and 500W models; 2, 4 and 6 zones, in stand-alone or networked configuration) and related accessories.
    PART NUMBER:
    SW038118
    DXT 3000 PLANNER
    Features
    • Control center planning
    • Design and optimize speakers installation
    • Automatic document creation
    • Design multiple Zones and ADAs
    • Based on UNI-CEN / TS 54-32 & UNI-ISO 7240-19
    • 100V Line Calculator
    • Microsoft Windows compatible
  • Description
    Pair of sealed lead acid batteries, 12V - 18Ah each.
    PART NUMBER:
    13360317
    BATT 18AH 2X
    EAN 8024530015923
    Features
    • Batteries for DXT 3000 systems
  • Description
    IT 3010 is an additional board for DXT 3000 Voice Alarm system to be used only in combination with IE 3008 interlink board. Thanks to its six line transformers, it is helpful in all those installations where audio signal may be affected by high noises along system’s units connections. Moreover, it offers the possibility to connect DXT 3000 units using both removable screw terminals and RJ 45 plugs, improving installation efficiency and flexibility.
    PART NUMBER:
    12399049
    IT 3010
    EAN 8024530016388
    Features
    • Installation on IE 3008
    • 6 line transformers
    • Screw or RJ 45 connectors
    • Power supply not required
  • Description IE 3008 is an additional board for DXT 3000 Voice Alarm system that extends its capability and functionalities allowing the connection of a maximum of eight units, in a master/slave configuration. It shall be installed inside the cabinet of each unit, that provides the necessary power supply. System's units communicate through a fully redundant bus, transporting commands and two audio channels. Up to four emergency consoles can be connected to the master unit, for the activation of both pre-recorded and live messages on each system’s zone, using dedicated BE 3806 additional keyboards. At system level, BGM can be injected in the master unit in the dedicated input, with global mute functionality. At local level, BGM can be enabled on each unit using the specific hardware setting. PART NUMBER: 12399015 IE 3008 EAN 8024530015152 Features
    • Connects up to 8 units
    • Master/slave architecture
    • Fully redundant communication bus
    • Powered by master unit
    • General and zone alarm activation
    • Global and local BGM inputs
     
  • Description
    MG 3006 is an additional board for DXT 3000 master units. It allows monitoring system’s General Purpose Inputs (GPI), detecting and reporting open line faults or short circuits along the path between DXT 3000 and other emergency devices, such as alarm buttons. It shall be installed inside the master unit, and powered directly by the system.
    PART NUMBER:
    13360344
    MG 3006
    EAN 8024530013356
    Features
    • Faults detection and reporting
    • General and zone alarm activation
    • Reset function
    • Powered by master unit
  • Description
    ME 3801 is a wall-mount emergency microphone exclusively dedicated to DXT 3000 Voice Alarm system, and can be used for live announcements during emergency situations. It features complete self-diagnostic functionalities and system status reporting in compliance with EN 54-16:2008 standard. Up to four microphones can be daisy-chained on the line, the first of those has emergency functions and it is powered directly by the master unit, while the others need local 24 V DC adapters.
    PART NUMBER:
    14322030
    ME 3801
    EAN 8024530015732
    Features
    • Live emergency announcements
    • General call functionality
    • Complete self-diagnostic
    • Powered by master unit
    • Handheld microphone with PTT button
    • Robust metal case
  • Description
    The A 1360 accessory is an adapter designed for surface mount installation of the PL 60 ceiling speaker. It is made of plastic UL94 V0 with rear plate in metal, providing an excellent aesthetic and functional combination with the speaker.
    PART NUMBER:
    13320107
    A 1360
    EAN 8024530015794
  • Description
    Insulation transformer in mumetal, removable screw terminals. Accepts signals at line level.
    PART NUMBER:
    17120056
    OT 3500
    EAN 8024530015985
    Features
    • Removable screw terminals
  • Description
    The MMU 3100 master unit includes all the features necessary to set-up a meeting for up to 80 microphone sets. Recording output and playback input are present as well, together with a dedicated input and output for teleconference system interfacing. The unit is able to provide 80W on its 100V or 70V output for the connection of additional sound reinforcement speakers present in the room. One line level output is available too, for the link to an independent sound reinforcement system. User controls are on front panel and include volume levels for inputs and powered outputs, directed to the reinforcement speakers integrated in each microphone console and to the ones connected to the amplifier direct output. Two devices MMU 3100 can be linked through a dedicated port, to expand the number of the delegate microphones to 160.
    PART NUMBER:
    17180042
    MMU 3100
    EAN 8024530010195
    Features
    • Input to connect up to 80 microphone sets with volume and voice EQ controls
    • Additional universal input on both XLR and removable screw terminals for lectern microphone or interview microphone or other sources with volume and voice EQ controls
    • Phantom power available
    • Input and outputs connections to an external recorder/player device, PLAY / REC selector switches with LED indicators. Volume control and tone EQ on PLAY-OUT
    • Teleconference dedicated input and output
    • Sound reinforcement and recording system output
    • Built-in power amplifier to feed the consoles speakers with volume selector
    • Built-in 80W power amplifier output with volume control for additional constant voltage sound reinforcement speakers
  • Description
    The DEC 6104 board is to be installed into the DMU 6100 main unit of the RCF FORUM 6000 conference system. This board adds features: Up to 180 DMS 6410 microphone consoles, USB port to connect the system to a PC, RS 485 port (alternative to the USB port), Anti-feedback processor, useful to avoid feedbacks due to loudspeakers too close to microphones, loudspeaker high volume and many open microphones at the same time. Included is the software FSW 6000 that manage and control the conference system.
    PART NUMBER:
    17180034
    DEC 6104
    EAN 8024530006723
    Features
    • Up to 180 DMS 6410 microphone consoles on 6 lines (4 line outputs are on the DEC 6104 board)
    • The further 120 consoles shall be powered by the DPS 6202 power supply unit
    • USB port to connect the system to a PC
    • FORUM 6000 control software included
    • RS 485 port (alternative to the USB port) for long distance control (up to 1.2 km) of the system through the PC software
    • Anti-feedback processor, useful to avoid feedbacks due to loudspeakers too close to microphones, loudspeaker high volume and many open microphones at the same time. PLAY INPUT
  • Description
    The DMU 6100 the heart of the system allowing the direct connection of up to 60 microphone sets on two lines. Specific tools are available on the DM 6100 to test the correct wiring and operation of the system to help installation and maintenance. The status is available on the LCD, including advice of the type of consoles connected. From the front panel of the main unit LCD, function buttons and LEDs help the installer and the user in adjusting all the parameters and volumes, while a speaker and a ¼” jack work as audio monitoring
    PART NUMBER:
    17180010
    DMU 6100
    EAN 8024530005696
    Features
    • Two universal inputs for connecting any additional sources such as a wireless microphone or a lectern microphone or any other complementary device, even a mixer-preamplifier.
    • Two inputs can be configured in different ways; for instance they can be mixed with the system audio, have priority on system microphone sets, one mixed and one priority etc.
    • Dedicated IN and OUT connections are available echo-free for the link to a teleconference system
    • VOX operation or command operation are available
    • The command switch can be programmed to work as FORCED-ON or FORCED-OFF always through configuration menu
    • REC-PLAY input and outputs associated to a switch allow the connection of any recorder/player.
    • 4 additional Auxiliary Outputs are available for the independent recording of the 2 universal inputs and each of the 2 lines of microphone sets
  • UP Series

    $0.00$1,999.00
  • Description
    PR 4093 has been designed to provide a flexible solution for paging and music application in PA systems. It offers 6 balanced inputs mic/line with PHANTOM facility, the first of them with priority triggered by VOX circuit. In addition, 3 stereo input on RCA connectors are available. Outputs offer different functionalities, included tone control on front panel, dedicated mixing of inputs 1-6 e connection to recording devices.
    PART NUMBER:
    17100003
    PR 4093
    220-240V, EAN 8024530013677
    17100007
    PR 4093
    115V, EAN 8024530015367
    Features
    • 6 balanced XLR inputs with MIC/LINE sensibility and selectable PHANTOM power
    • 3 stereo inputs on RCA connectors
    • SIGNAL presence LED for each input
    • Priority function on input 1, activatable through VOX circuit
    • 1 XLR stereo output with tone control LOW, MID, HIGH on front panel
    • 1 MONO output on ¼'' jack connnector
    • 1 MIC output on ¼'' jack connnector
    • Connection to recording device on RCA connectors
    • LED output level indicator
    • 230V AC functioning and 24V DC emergency power supply
PR 4093